Navigate to:
Air Purification Systems
Safe-T Air Purification products offer superior air purification through sophisticated filtration systems, high volume air flow capacity, and lower sound levels than any other premium air purifier on the market today. The Air Purifier is a Medical Grade Air System capable of filtering the air 3 times per hour at a very low noise level and the lowest cost per cubic feet of air cleaned.
SCA Air Purifier
As the air is drawn through the bottom of the unit, it passes through the HEPA-Rx Filter, the Activated Carbon Filter and the Germicidal UV-C+ Photocatalytic Nano-TiO2 chamber. At the final stage, the purified air moves through the Revitalizing Negative Ion Generators near the air outlet and releases negative ions into the air.
Touchless Control
Hand Gesture Control Sensor helps prevent cross-contamination
Digital display
Shows levels of air flow, power, light and UV indicator
Absorption Process
Activated Carbon Insert
Absorbs VOC's (Volatile Organic Compounds)
Re-Energize the Air
The negative ion generator makes indoor air feel more pure, clean and energized.
Virus & Bacteria destruction
Ultraviolet Light (UV) & Titanium Dioxide Chamber (T102) degrades chemicals, damages bacterial membranes, inactivates viruses and oxidizes VOC's
Particles Capture
HEPA-Rx Filter removes 99.998% of particles at 0.1 microns in size, the size of a typical virus
Premium Commercial Grade
Cleans and Sanitizes Indoor Air
Safe-T air purification systems systems use a 4-step, 6- stage air purification process doesn’t just remove the smallest particulates of pollution, it DESTROYS them.
The Pre-Filter & HEPA-Rx Filter stage captures even ultra-fine particulates, with 99.998% of particles at 0.1 microns and 99.2% of particles at 0.0025 microns.
Covid-19 virus is at 0.12 microns.
High Volume Air Flow
To achieve the best air quality, it is advised to reach 4-6 air changes per hour (ACH). Safe-T Air Purification products make 3 ACH. Together with an HVAC system which makes 1-2 ACH, any space regardless of its size receives maximum ACH required.
To calculate a correct number of air purification units in a space, the following factors are taken into consideration: air changes per hour, air flow rate, and a space size including ceiling height, room length and width.
Touchless Control
Wave a hand above the air purifier to turn it on and off and to switch between the work modes to ensure safety and avoid cross-contamination.
Whisper Quiet
Noise-canceling sound dampening design keeps the sound volume at very low levels 30dBA - 55dBA
Stands
The stands raise air intake to mouth level. The two heights are designed to draw air in from 360 degrees around the air purification devise in standing or seated position. Mobile stand features heavy-duty locking casters that can easily transport air purification unit to another area. Aesthetically pleasing design seamlessly blends in any interior space.
6 Stages of Air Purification
Filter
particles in the air
Filter
and gases
Nano-TiO2
microorganisms
UV-C+
and bacteria, effectively
destroying them
Industrial Strength
Meets MERV (13-16) Categorization of ANSI Standard 52.2
Safe-T air purification systems utilize multi-stage air purifying technologies that work together to clean, purify and re-energize the indoor air.
Don’t Just Filter Pollutants - Destroy Them
The multi stage filtration system captures dust particles, pollen, volatile organic chemicals (VOCs), mold, allergens, viruses, odors (like formaldehyde and smoke), bio-aerosols, nitrous oxide, and many other pollutants that are found in the air*.
Dust Particles
Pollen
Volatile Organic Chemicals
Mold
Allergens
Viruses
Odors
Bio-Aerosols
Nitrous Oxide
Formaldehyde
When do the filters need to be changed?
The HEPA-Rx filter needs to be changed once a year
(running 24/7)
The Activated Carbon filter needs to be changed 3 times a year
(running 24/7)
The Germicidal UV-C+ needs to be changed just under one year
(running 24/7)
Trusted & Loved By
Specifications
Model Name | SCA-B / SCA-W | SCA-X-B / SCA-X-W |
Dimensions | 26"H x 12"W | 33.5"H x 12"W |
Weight | 25.4 lbs | 30.6 lbs |
Fan Speed | 4 Speeds, Auto Mode | 4 Speeds, Auto Mode |
Sound Level (Measured at 6ft) | Low <30dBA | High <55dBA | Low <30dBA | High <55dBA |
Ultrafine Particle Filter | HEPA-Rx | HEPA-Rx |
Activated Carbon Filter | ||
Germicidal UV-C+ Bulbs | ||
Hydroxyl Radical Reactivity Chamber | ||
Revitalizing Negative ION Chamber | ||
Auto Function | ||
Air Quality Sensors | ||
Control Panel | Hand Wave Sensor | Hand Wave Sensor |
Power | 120V, 60HZ | 120V, 60HZ |
CARB Compliance |
Calculator
Use Enclosed Space calculator for private offices or classrooms. Use Open Space calculator for large open plan areas.
- SCA-X
- SCA
Enclosed Space
Open Space
Enclosed Space
Open Space
Request Estimate
Resources & Downloads
Growth 500
Canada’s Fastest-Growing Companies
(2018, 2019, 2020)
Report on Business
Canada’s Top Growing Companies
(2019, 2020)
Financial Times
The Americas’ Fastest Growing
Companies (2020)
Upper Room GuardUV Germicidal Air Purifier
Safe-T GuardUV Germicidal Ultraviolet Air Purifier destroys airborne pathogens by generating a controlled region of germicidal UV light in the upper regions of a room. Pathogenes are drawn through the UV lamp chamber, exposing them to high-intensity germicidal UV light and then released into the upper air of the room where they are exposed to additional focused UV light. The UV light disinfection field is restricted to the upper area of the room (must be installed at least seven feet from the floor).
Features
- Wall mount and bi-directional ceiling fan models
- 22 and 33 inch UV lamp models
- Quiet 67 cfm fan (30 db)
- 9,000 hour UV lamp life - over 3-years running 8 hours per day
- Energy efficient
- Galvanized steel construction
- Powerful air movement with 67 cfm fan
- UV air disinfection is recognized and endorsed by ASHRAE, The American Society of Heating, Refrigerating and Air-Conditioning Engineers
- 6' cord is included with an option to hardwire or plug-in
Wall or Ceiling Mount Models
STG-33F Wall Mount
STG-33F-CR Celing Mount
37 5/8” wide
STG-22F Wall Mount
STG-22F-CR Ceiling Mount
26 1/8” wide
Front-rear bi-directional
Ceiling Mount
35 1/8” wide
Important: the 7-foot minimum installation height requirement must be observed to assure the safety of the occupants.
UV Effectiveness Against Various Microbes
Percentage disinfection calculations are based on the intensity at end of (9,000 hours) lamp life *There are many strains of coronavirus that have been identified, this chart lists just two
Air Flow
Specifications
Model Name | STG-22F | STG-33F | STG-22F-CR | STG-33F-CR |
Coverage, sq. ft. | 225 (15’x15’) | 350 (16’x22’) | 450 (15’x30’) | 700 (16’x44’) |
Application/mount | wall | wall | ceiling | ceiling |
Total UV-C output | 10w | 16w | 10w | 16w |
UV lamp wavelength | 254nm | 254nm | 254nm | 254nm |
UV lamp life | 9,000 hrs | 9,000 hrs | 9,000 hrs | 9,000 hrs |
Power consumption | 36.5VA | 44.5VA | 36.5VA | 44.5VA |
Width | 26.1” | 37.7” | 26.1” | 37.7” |
Height | 6.1” | 6.1” | 6.1” | 6.1” |
Depth | 9.2” | 9.2” | 13.5” | 13.5” |
Net Weight | 13 lbs. | 15 lbs. | 15 lbs. | 19 lbs. |
Gross Weight | 18 lbs. | 20 lbs. | 20 lbs. | 24 lbs. |
Power: All models auto-sensing 120-277 VAC, 50/60 hz.
Important: When installed, bottom of fixture must be at least 7 feet above the floor.
Memberships
EPA establishment number: 074725-VT-001
Resources & Downloads
Portable UV Photomax Air Purifier
Cleaner, Healthier Indoor Air.
Breaks down Odors, VOCs,
and Toxins, Kills Bacteria and Viruses
Reduces Allergens.
Features
- Commercial-grade Stainless Steel outer cabinet with steel chassis
- Self cleaning, the carbon blocks are continually restored by the PCO process and need no maintenance
- No Ozone produced
- UL 2998 compliant
- Compact: 9”x 9” - 3” high
- Quiet fan
- Washable pre-filter
- Low power consumption
- Covers areas up to 800 sq ft
- Plugs into standard 110VAC outlet; hardwire available
- Wall mount option included
Air Flow
Converts complex air contamination back to normal air components
Specifications
Part Number | STG-UVP |
Coverage | up to 800 sq. ft. |
Power Connection | Standard 110VAC outlet |
Weight | 4 lbs. |
Dimensions (W x D x H) | 9”x9”x3” |